15 Amp Circuit Breaker
The 15 Amp Circuit Breaker series encompasses essential protection and control devices for residential, commercial, and light industrial applications, including MCBs, RCCBs, RCBOs, and contactors—all rated for 15A current to safeguard low-voltage circuits.
All models comply with IEC/EN standards, featuring compact DIN rail mounting and durable construction for reliable performance in everyday electrical setups.
MCB YCB9N-40
1P+N | 6-40A | B, C | 6kA | 18mm | CE EAC
Slim design, space-saving, ideal for residential distribution.
MCB YCB9-63
1-4P | 1-63A | B, C, D | 4.5kA, 6kA | CE CB EAC
Full range, rich accessories, for residential and commercial use.
MCB YCB9-63R
1-4P | 1-63A | B, C, D | 15kA, 25kA | CE EAC
High breaking capacity, for critical circuit protection.
MCB YCB9-80M/H
1-4P | 1-80A | 8-12In, B, C, D | 15kA, 25kA | CE CB EAC
Reliable performance, dual busbar connection, for industrial use.
MCB YCB9-125
1-4P | 10-125A | 8-12In, C, D | 4.5kA, 6kA, 10kA | CE EAC
High-current MCB, for main circuits or heavy loads.
RCBO YCB9NL-40
1P+N | 2-40A | B, C | 6kA | 18mm | CE EAC
Compact RCBO, ideal for residential terminal protection.
RCBO YCB9NL-40LS
1P+N | 2-40A | A | 6kA | 18mm | CE EAC
Type A RCD, neutral line detection, for smart distribution.
RCBO YCB9HL-63
1P+N | 6-63A | B, C | 6kA | CE EAC
Electromagnetic type, dual-handle design, clear fault indication.
RCBO YCB9LE-80M/H
1P+N, 3P+N | 10-80A | B, C, D | 6kA, 10kA | CE EAC
Electronic RCBO, for commercial and industrial distribution.
Interlocked Contactor CJX2s-MN
3P 4P | 6-16A | AC/DC| CE
Mechanical interlock, for interlocked or reversing control.
Interlocked Contactor CJX2s-N
3P 4P | 9-95A | AC/DC| CE
Electrical interlock, for interlocked or reversing control.
CNC 15 Amp Circuit Breaker
Used in AC 50/60Hz, 230V lines with rated current up to 40A for overload, short circuit protection, and isolation, suitable for residential buildings, non-residential buildings, energy industry, and infrastructure, supporting infrequent line connection, disconnection, and switching under normal circumstances.
Compliant with IEC/EN 60898-1 standard.
Pole configuration: 1P+N.
Tripping characteristics: B/C/D options (thermal magnetic release); Type B (3-5In), Type C (5-10In).
Rated current: within 6-40A range.
Electrical life: 8000 times.
Mechanical life: 20000 times.
Installation: Mounted on DIN rail EN 60715 (35mm) via fast clip device; wiring from top and bottom.
Terminal connection: Cable/pin-type busbar (max 16mm² for cable, 10mm² for busbar).
Tightening torque: 2N·m.
Solution
We provide our customer with profitable growth by offering integrated comprehensive electrical solution.
Bulk Wholesale
Global supply chain support with competitive pricing for large quantity orders. Dedicated account managers and flexible delivery terms.
WhatsApp: +8618958711903 E-mail: marcom@cncele.comOEM Partnership
Custom manufacturing solutions tailored to your brand requirements with strict quality control and confidential production.
Dealer Network
Join our global dealer program with exclusive territories, marketing support, and technical training resources.
FAQ
Typically 8–10 outlets (1.5A per outlet average) to avoid exceeding 80% of capacity (12A continuous load).
No. 15A circuits use 14-gauge wire, which is unsafe for 20A loads—risk of overheating/fire. Always match breaker to wire size.
Small appliances (coffee makers, microwaves), lighting, TVs, laptops, and home electronics (total ≤1,800W at 120V).
Signs: frequent tripping, hot-to-touch panel, burning odors, failure to reset, or loose switch. Replace if unresponsive.
Yes, we offer OEM/ODM customization for ATS, including branding, specifications, and design tailored to client requirements.
Lead time varies by region and order volume; contact our team for a detailed quote based on your location.
Please reach out to our sales team via [cncele@cncele.com/WhatsApp:+86 18958711903] for authorized distributor information in your region.
-