4 Pole MCB
4 Pole MCB
4 Pole MCB

4 Pole MCB

Global distribution network

Global Presence

CNC Electric delivers safe and reliable low-voltage electrical solutions across 130+ countries, supporting 30+ exclusive distributors and 200+ CNC stores worldwide.

Our commitment to localization and market expansion ensures tailored solutions for different regions, backed by strategic partnerships, dedicated service teams, and participation in leading industry exhibitions such as MEE, Elektro, Electric & Power, Canton Fair and etc.

Learn More

4 Pole Miniature Circuit Breakers

Our 4 Pole MCB Series offers versatile circuit protection solutions with configurable pole options (1P to 4P), current ratings from 1A to 125A, and trip characteristics (Type B/C/D) to suit diverse electrical systems. Engineered for reliable overload and short-circuit protection, these MCBs feature compact design and seamless integration into residential, commercial, and industrial distribution networks.

YCB9-63 MCB
1–63A | 1P/2P/3P/4P | Type B/C/D | EC/EN 60898-1
YCB7-125N 4P MCB
63–125A | 1P/2P/3P/4P | Type C/D | IEC/EN 60947-2
YCB6 MCB
1–63A | 1P/2P/3P/4P | Type B/C/D | IEC/EN 60898-1
YCB9-125 MCB
10–125A | 1P/2P/3P/4P | Type C/D | IEC/EN 60898-1,IEC/EN 60947-2
YCB9-80M/H MCB
1–80A | 1P/2P/3P/4P | Type B/C/D | IEC/EN 60898-1
YCB7-63N MCB
1–80A | 1P/2P/3P/4P | Type B/C/D | IEC/EN 60898-1

Explore Our Complete Product Catalog

Download Catalog PDF
Why Choose

CNC MCB

The YCB7-125N Miniature Circuit Breaker (MCB) is designed for AC 50/60Hz circuits with rated voltage up to 400V and rated current ranging from 10A to 125A, providing overload and short-circuit protection. Suitable for industrial, commercial, high-rise, and residential applications.

Key Features:

High flame retardancy, heat resistance, and impact resistance.
6000A short-circuit breaking capacity.
Contact indication window for easy ON/OFF status monitoring.

Core Specs:

Compliance: IEC 60947-2, IEC 60898-1.
Poles: 1P/2P/3P/4P.
Rated voltage: AC230V/400V (1P/2P), AC400V (3P/4P).
Thermo-magnetic release: Type C (8In) or D (12In).
Insulation voltage: 500V; impulse withstand voltage: 6kV.
Installation: DIN rail EN 60715 (35mm).

Solution

We provide our customer with profitable growth by offering integrated comprehensive electrical solution.

Bulk Wholesale

Global supply chain support with competitive pricing for large quantity orders. Dedicated account managers and flexible delivery terms.

WhatsApp: +8618958711903

OEM Partnership

Custom manufacturing solutions tailored to your brand requirements with strict quality control and confidential production.

Dealer Network

Join our global dealer program with exclusive territories, marketing support, and technical training resources.

Relevant Case

Angola's Natural Gas Processing Plant Project

Angola's Natural Gas Processing Plant Project

Donglin Cement Plant Electrical Distribution System Upgrade

Donglin Cement Plant Electrical Distribution System Upgrade

Nigeria Water Pump Control Solution Project

Nigeria Water Pump Control Solution Project

Nikopol Ferroalloy Plant Electrical Upgrade

Nikopol Ferroalloy Plant Electrical Upgrade

Nikopol Ferroalloy Plant Upgrade

Nikopol Ferroalloy Plant Upgrade

Project Introduction for Bulgarian Factory Electrical Project

Project Introduction for Bulgarian Factory Electrical Project

See more cases>>>

FAQ

Here are concise FAQ responses for the 4 Pole MCB series:

What is 4 pole in MCB?

A 4-pole MCB refers to a miniature circuit breaker with four separate current-carrying poles, designed to disconnect all three phase conductors and the neutral line simultaneously during tripping or manual operation.

What is a 4 pole breaker used for?

4-pole breakers are primarily used in three-phase electrical systems to provide complete isolation of all conductors (phases + neutral). They are ideal for sensitive equipment, industrial machinery, or installations requiring neutral line protection, ensuring enhanced safety during maintenance or fault conditions.

What is the difference between 4 pole MCB and TPN?

A 4-pole MCB switches all four conductors (3 phases + neutral), while TPN (Three Pole and Neutral) breakers typically switch the three phases but leave the neutral line permanently connected. 4-pole designs offer full isolation, whereas TPN focuses on phase-only protection.

What is the difference between 2 pole and 4 pole MCB?

2-pole MCBs control two conductors (line + neutral) for single-phase systems (common in residential use), while 4-pole MCBs manage three phases + neutral for three-phase applications (industrial/commercial settings). The key distinction lies in the number of conductors isolated and their intended electrical system type.

What is the lead time for MCB orders?

Lead time varies by region: typically 1–2 weeks for standard models. Custom orders may take 3–4 weeks. Contact sales for exact timelines.

Do you support OEM for MCB products?

Yes, we offer OEM services, including custom branding, packaging, and specifications tailored to your needs.

What certifications do your MCBs have?

Our MCBs comply with global safety standards (e.g., IEC, CE) to ensure reliability and regulatory compliance.

How to contact a distributor for MCB purchases?

For local distributor info or bulk inquiries, please contact our sales team via email (cncele@cncele.com) or WhatsApp (+86 18958711903).

CNC=CREATE+NEW+CENTURY