63 Amp Circuit Breaker
63 Amp Circuit Breaker
63 Amp Circuit Breaker

63 Amp Circuit Breaker

Global distribution network

Global Presence

CNC Electric delivers safe and reliable low-voltage electrical solutions across 130+ countries, supporting 30+ exclusive distributors and 200+ CNC stores worldwide.

Our commitment to localization and market expansion ensures tailored solutions for different regions, backed by strategic partnerships, dedicated service teams, and participation in leading industry exhibitions such as MEE, Elektro, Electric & Power, Canton Fair and etc.

Learn More

63 Amp Circuit Breaker

CNC’s 63 amp breakers are designed for long service life, with features like adjustable trip settings (in some models) and compatibility with modern electrical systems.

Mini Brekaer
1–63A | B, C, D | 6kA | IEC/EN 60898-1
YCB7LE-63Y 63A RCCB
6–63A | B, C, D | 6kA | AC/A Type (Earth Leakage Sensing)
YCB7RL-100 63A RCCB
6–100A | A, AC | 6kA/10kA | Electromagnetic Earth Leakage Type
YCM8E 63A Brekaer
salt/oil/mold/nuclear res. | overload/short/ground prot. | DIP+accessories
Voltage-Protecto
3/4P | Rated Current:200-400/400-630/400-800A | Breaking Capacity:35/25,50/35kA
DIN-Rail-Indicator
L/M-type (Icu) |land/marine | AC50Hz | ≤1600A | IEC60947-2
DIN-Rail-Indicator
AC 50/60Hz, ≤690V, 12.5-1600A | IEC 60947-2
DIN-Rail-Indicator
1P/2P, 3P/4P | B/C/D | 15kA | 500V Ui

Explore Our Complete Product Catalog

Download Catalog PDF
Why Choose

CNC 63A Circuit Breaker

Used in AC 50/60Hz, 230V lines with rated current up to 63A for leakage (electric shock), overload, and short circuit protection, suitable for infrequent connection, disconnection, and switching.

Compliant with IEC/EN 61009-1 standard.

Pole configuration: 1P+N.

Tripping characteristics: B/C/D options.

Rated current: 63A.

Rated residual operating current: default 30mA (100mA/300mA available).

Residual current type: default AC Type (A Type optional).

https://www.cncele.com/rccb-63a-30ma-2-pole-product/

Solution

We provide our customer with profitable growth by offering integrated comprehensive electrical solution.

Bulk Wholesale

Global supply chain support with competitive pricing for large quantity orders. Dedicated account managers and flexible delivery terms.

WhatsApp: +8618958711903

OEM Partnership

Custom manufacturing solutions tailored to your brand requirements with strict quality control and confidential production.

Dealer Network

Join our global dealer program with exclusive territories, marketing support, and technical training resources.

63 Amp Circuit Breaker: A Complete Guide to Functionality, Applications, and Key Insights

CNC 63 amp circuit breakers are critical electrical components designed to protect circuits from overcurrent, short circuits, and electrical faults. Engineered for reliability and precision, these breakers combine advanced tripping mechanisms with durable construction, making them ideal for industrial, commercial, and residential electrical systems.

What is a Control Relay?

Before diving into 63 amp circuit breakers, it’s helpful to understand the broader role of control components in electrical systems. A control relay is a foundational device that uses a small electrical signal to switch larger currents, enabling automation and safety in circuits. While relays manage signal flow, circuit breakers like the 63 amp variant focus on protecting circuits by interrupting power when dangerous current levels are detected.

What is a 63 Amp Circuit Breaker?

A 63 amp circuit breaker is a specialized overcurrent protection device rated to handle up to 63 amps of continuous current. Unlike basic fuses, it offers reusable protection: when an overload or short circuit occurs, its internal mechanism trips to cut power, and it can be manually reset after the fault is resolved. CNC’s 63 amp breakers are designed for long service life, with features like adjustable trip settings (in some models) and compatibility with modern electrical systems.

Key Differences: 63 Amp Circuit Breakers vs. Standard Relays

While both devices play roles in electrical control:

63 amp circuit breakers prioritize safety by preventing damage from excessive current.

Relays focus on signal switching and automation.

CNC’s 63 amp breakers integrate robust materials (e.g., flame-retardant casings, high-conductivity contacts) to ensure performance in demanding environments, from factory floors to commercial buildings.

How Does a 63 Amp Circuit Breaker Work?

Current Monitoring: The breaker continuously measures current flow through its conductive path.

Tripping Mechanism: If current exceeds 63 amps (or a preset threshold in adjustable models), a bimetallic strip heats and bends, triggering the breaker to open. For short circuits, an electromagnet rapidly activates the trip.

Power Interruption: Once tripped, the breaker disconnects the circuit, preventing overheating or fire.

Types of 63 Amp Circuit Breakers (Common Variants)

MCB (Miniature Circuit Breaker): Compact, designed for low-voltage applications (e.g., residential distribution boards, small machinery).

MCCB (Molded Case Circuit Breaker): Larger, with adjustable trip settings for industrial use (e.g., motor control centers, heavy machinery).

GFCI/AFCI-Enabled: Some CNC 63 amp models include ground-fault or arc-fault detection for enhanced safety in sensitive environments.

Benefits of CNC 63 Amp Circuit Breakers

Durability: Resistant to mechanical wear and thermal stress, ensuring reliable performance over years.

Flexibility: Available in fixed or adjustable trip ratings to suit diverse load requirements.

Safety Compliance: Meets global standards (e.g., IEC, UL) for overcurrent protection.

What is a 63 Amp Breaker Used For?

63 amp circuit breakers are versatile, with applications including:

Industrial Machinery: Protecting high-power equipment like pumps, compressors, and conveyor systems.

Commercial Buildings: Serving as main breakers in office or retail distribution panels to safeguard lighting, HVAC, and IT systems.

Renewable Energy: Integrating with solar inverters or wind turbine systems to manage fluctuating currents.

Residential Upgrades: Used in large homes with high-power appliances (e.g., electric stoves, heat pumps) where standard 32-40 amp breakers are insufficient.

What is the Load Capacity of 63 Amp MCB?

A 63 amp MCB (Miniature Circuit Breaker) is rated to carry a continuous load of 63 amps under normal operating conditions (e.g., ambient temperatures of 30°C). However, factors like ambient heat (higher temps reduce capacity), cable size (undersized wiring may limit effective load), and inrush currents (temporary spikes during motor startup) can affect real-world performance. For critical applications, consulting a certified electrician to verify load compatibility is recommended.

63 Amp Circuit Breaker Price Considerations

The cost of a 63 amp circuit breaker varies based on type, features, and brand. MCBs are typically more affordable ($20-$50) than MCCBs ($80-$200+). Models with GFCI/AFCI protection or smart connectivity (e.g., remote monitoring) command higher prices. While CNC’s breakers may be slightly above generic options, their reputation for quality and long-term reliability justifies the investment.

Real-World Applications of 63 Amp Circuit Breakers

Factory Automation: Protecting assembly line motors from overloads during peak production.

Data Centers: Safeguarding backup generators and UPS systems.

EV Charging Stations: Managing high currents in commercial electric vehicle chargers.

Agricultural Equipment: Ensuring reliability in irrigation pumps and grain processing machinery.

Whether you’re upgrading a residential panel or designing an industrial electrical system, a CNC 63 amp circuit breaker offers the safety and performance needed to keep operations running smoothly. For tailored recommendations, contact CNC’s technical team to match your specific load requirements with the right breaker model.

CNC Electric 产品图 width="800" height="600" decoding="async">