63 Amp Miniature Circuit Breaker
63 Amp Miniature Circuit Breaker
63 Amp Miniature Circuit Breaker

63 Amp Miniature Circuit Breaker

Global distribution network

Global Presence

CNC Electric delivers safe and reliable low-voltage electrical solutions across 130+ countries, supporting 30+ exclusive distributors and 200+ CNC stores worldwide.

Our commitment to localization and market expansion ensures tailored solutions for different regions, backed by strategic partnerships, dedicated service teams, and participation in leading industry exhibitions such as MEE, Elektro, Electric & Power, Canton Fair and etc.

Learn More

63 Amp Miniature Circuit Breaker

The 63A Miniature Circuit Breaker (MCB) is a compact, reliable protection device for AC 50/60Hz circuits, supporting rated voltages up to 400V. It safeguards against overloads and short circuits in residential, commercial, and light industrial setups, ensuring circuit safety for appliances, lighting, and power tools.

YCB9-63 MCB
1–63A | 1P/2P/3P/4P | Type B/C/D | EC/EN 60898-1
YCB7-125N MCB
63–125A | 1P/2P/3P/4P | Type C/D | IEC/EN 60947-2
YCB3-63 MCB
1–63A | 1P/2P/3P/4P | Type B/C/D | IEC/EN 60898-1,IEC/EN 60947-2
YCB9-125 MCB
10–125A | 1P/2P/3P/4P | Type C/D | IEC/EN 60898-1,IEC/EN 60947-2
YCB9-80M/H MCB
1–80A | 1P/2P/3P/4P | Type B/C/D | IEC/EN 60898-1
YCB7-63N MCB
1–80A | 1P/2P/3P/4P | Type B/C/D | IEC/EN 60898-1
YCB6-63 MCB
1–63A | 1P/2P/3P/4P | Type B/C/D | IEC/EN 60898-1
YCB6-125 MCB
6–125A | 1P/2P/3P/4P | Type B/C/D | IEC/EN 60898-1

Explore Our Complete Product Catalog

Download Catalog PDF
Why Choose

CNC 63 Amp MCB

The YCB7-125N Miniature Circuit Breaker (MCB) is designed for AC 50/60Hz circuits with rated voltage up to 400V and rated current ranging from 10A to 125A, providing overload and short-circuit protection. Suitable for industrial, commercial, high-rise, and residential applications.

Key Features:

High flame retardancy, heat resistance, and impact resistance.
6000A short-circuit breaking capacity.
Contact indication window for easy ON/OFF status monitoring.

Core Specs:

Compliance: IEC 60947-2, IEC 60898-1.
Poles: 1P/2P/3P/4P.
Rated voltage: AC230V/400V (1P/2P), AC400V (3P/4P).
Thermo-magnetic release: Type C (8In) or D (12In).
Insulation voltage: 500V; impulse withstand voltage: 6kV.
Installation: DIN rail EN 60715 (35mm).

Solution

We provide our customer with profitable growth by offering integrated comprehensive electrical solution.

Bulk Wholesale

Global supply chain support with competitive pricing for large quantity orders. Dedicated account managers and flexible delivery terms.

WhatsApp: +8618958711903

OEM Partnership

Custom manufacturing solutions tailored to your brand requirements with strict quality control and confidential production.

Dealer Network

Join our global dealer program with exclusive territories, marketing support, and technical training resources.

Relevant Case

Angola's Natural Gas Processing Plant Project

Angola's Natural Gas Processing Plant Project

Donglin Cement Plant Electrical Distribution System Upgrade

Donglin Cement Plant Electrical Distribution System Upgrade

Nigeria Water Pump Control Solution Project

Nigeria Water Pump Control Solution Project

Nikopol Ferroalloy Plant Electrical Upgrade

Nikopol Ferroalloy Plant Electrical Upgrade

Nikopol Ferroalloy Plant Upgrade

Nikopol Ferroalloy Plant Upgrade

Project Introduction for Bulgarian Factory Electrical Project

Project Introduction for Bulgarian Factory Electrical Project

See more cases>>>

FAQ

Q: What is a 63 amp MCB used for?
A 63 amp miniature circuit breaker protects electrical circuits from overloads and short circuits. Ideal for high-power applications like air conditioners, electric water heaters, or commercial lighting systems in homes, offices, or small industrial setups.

Q: How much load can a 63 amp MCB take?
A 63 amp MCB safely handles continuous loads up to ~50.4A (80% of rated current) to avoid overheating. For short-term surges (e.g., motor startup), it temporarily supports up to 63A.

Q: How to size a miniature circuit breaker?
Calculate the circuit’s maximum load current, add a safety margin (10-20% for motor/inductive loads), and match it to the MCB’s rated current. Ensure the MCB’s rating aligns with wire capacity (e.g., "63 amp mcb wiring diagram" guidelines) and IEC 60898 standards.

Q: What are the three types of miniature circuit breakers?
Commonly categorized by trip characteristics:

  • Type B: Sensitive (3-5x rated current), for lighting/small resistive loads.
  • Type C: Standard (5-10x), for general appliances (e.g., "63 amp mcb for domestic use").
  • Type D: Heavy-duty (10-20x), for motors/inductive equipment.

Q: What’s the delivery time for 63 amp MCB?
Standard models (e.g., "single phase 63 amp mcb") take 1-3 weeks; regional stock may vary. Custom orders require 4-6 weeks.

Q: Does it support OEM?
Yes! We offer OEM services—custom labeling, specifications, or packaging to fit your brand or project needs.

Q: What certifications does it have?
Compliant with global safety standards (covering CE, UL, etc.), ensuring reliability for international use.

Q: How to get 63 amp MCB pricing or contact dealers?
Pricing varies by type (B/C/D) and features. Visit our website or contact customer service for quotes and nearby authorized dealer info.

CNC=CREATE+NEW+CENTURY