CJX2s 09-25 AC Contactor | CNC Electric
CJX2s 09-25 AC Contactor
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

CJX2s 09-25 AC Contactor
Picture
Video
  • CJX2s 09-25 AC Contactor
  • CJX2s 09-25 AC Contactor
  • CJX2s 09-25 AC Contactor
  • CJX2s 09-25 AC Contactor
  • CJX2s 09-25 AC Contactor
  • CJX2s 09-25 AC Contactor
  • CJX2s 09-25 AC Contactor
  • CJX2s 09-25 AC Contactor
  • CJX2s 09-25 AC Contactor
  • CJX2s 09-25 AC Contactor
CJX2s 09-25 AC Contactor Featured Image

CJX2s 09-25 AC Contactor

CJX2s series AC Contactor with novel appearance and compact structure is suitablefor using starting &controlling the AC motor frequently,switching on and off thecircuitat a long distance.It is used in combinationwith thermal relay to compose amagneticmotor starter
StandardIEC60947-1,IEC 60947-4-1.

Contact Us

Product Details

cjx2s-product-description1
cjx2s-product-description2
cjx2s-product-description3
cjx2s-product-description4

General

CJX2s series AC Contactor with novel appearance and compact structure is suitable for using starting & controlling the AC motor frequently, switching on and off the circuit at a long distance. It is used in combination with thermal relay to compose a magnetic motor starter.
Standard: IEC 60947-1, IEC 60947-4-1.

• Rated operation current(Ie): 9-110A

• Rated operation voltage(Ue): 220V~690V

• Rated insulation voltage: 690V

• Poles: 3P

• Auxiliary contacts: 1NO+1NC;

• Installation: Din rail and screw installation

• Standard: IEC 60947-1, IEC 60947-4-1

Operating and Installation Conditions

Type Operating and Installation Conditions
Installation category III
Pollution level 3
Protection degree CJX2s-09~38: IP20; CJX2s-40~95: IP10
Ambient temperature limit of temperature: -35℃~+70℃,normal temperature: -5℃~+40℃,The average no more than +35℃ within 24 hours.
Altitude ≤2000m
Ambient temperature The maximum temperature is 70 degrees, the relative humidity of the air does not exceed 50%, and the temperature below 50% can allow higher relative humidity. If the temperature is 20℃, the air relative  humidity could up to 90%, Special measures should betaken for occasional condensation due to humidity changes.
Installation position Inclination between installation surface and vertical surface should not exceed ±5°
Shock vibration Products should be installed and used without significant shake, shock and vibration.

Overall and Mounting

CJX2s-09~38

cjx2s-product-description7

CJX2s-40~95

cjx2s-product-description8
F4-D, LA2-D, LA3-D Contact Block
LX1-D Coil
Derived Products When The Contactor is Assembled With Following Accessory Module
F4-D, LA2-D, LA3-D Contact Block

CX2S 110 AC contactor photo

LX1-D Coil
Type Product Coil

Frequency
(Hz)

voltage
Us(V)
24  36  42  48  110  127  220  230  240  380  400  415  440  600 
LX1S-D2
09-18

LX1S-D4
25-38

LX1S-D6
40-65

LX1S-D8
80-95

 LX1S Coil 50Hz B5 C5 D5 E5 F5 G5 M5 P5 U5 Q5 V5 N5 R5 X5
60Hz B6 C6 D6 E6 F6 G6 M6 P6 U6 Q6 V6 N6 R6 X6
50/60Hz B7 C7 D7 E7 F7 G7 M7 P7 U7 Q7 V7 N7 R7 X7
LX1S-D2
09-18
Wide voltage 50-60Hz AC/DC100-240V
LX1S-D4
25-38
50-60Hz AC/DC100-240V
Derived Products When The Contactor is Assembled With Following Accessory Module
Derived products Contactor Accessory module Picture
Time-delay
Contactor
 CJX2s AC Contactor Derived products
Reversing
Contactor
Magnetic
Starter
Front Auxiliary Contact
Side Auxiliary Contact
Changeover
Capacitor
AC Contactor
Dust Cover

Specifications

Type CX2s09 CX2s12 CX2s-18 CX2s25 CX2s32 CX2s38 CX2s40 CX2s50 CX2s65 CX2s80 CX2s95 CX2s-110
Main circuit characeristic  CX2S-09-AC-contactor-MCB  CX2S 18-25 AC contactor MCB  CX2S 32-38 AC contactor MCB  CX2S 40-65 AC contactor  CX2S 80-110 AC contactor
Poles 3P
Rated insulation voltage(Ui) V 690 
Rated operating voltage(Ue) V 380/400,660/690
Rated themal current(Ith),AC-1 20  20  32  40  50  50  50  60  80  125  125  140 
Rated operation
current(le)
AC-3,380/400V A 12  18  25  32  38  40  50  65  80  95  110 
AC-3,660/690V A 6.6  8.9  12  18  22  22  34  39  42  49  49  49 
AC-4,380/400V A 3.5  7.7  8.5  12  14  18.5  24  28  37  44  44 
AC-4,660/690V A 1.5  3.8  4.4  7.5  8.9  12  14  17.3  21.3  21.3 
Rated
operational
power(Pe)
AC-3,380/400V kW 5.5  7.5  11  15  18.5  18.5  22  30  37  45  45 
AC-3,660/690V KW 5.5  7.5  10  15  18.5  18.5  30  33  37  45  45  45 
AC-4,380/400V KW 1.5  2.2  3.3  5.4  5.5  7.5  11  15  18.5  22  22 
AC-4,660/690V KW 1.1  1.5  3.7  5.5  7.5  10  11  15  18.5  18.5 
Mechanical life 10000
times
1200  1000  900  650 
Electrical life AC-3 110  90  65 
AC-4 22  22  17  11 
Frequency of
operation
AC-3 times/
hour
1200  600 
AC-4 300  300 
Connecting capability of main circuit teminal
Flexible wire 1 wire mm² 1..4 1.5..6 2.5...25 4...50
No terminal 2 wire mm² 1...4 1.5..6 2.5...16 4...25
Flexible wire 1 wire mm² 1...4 1..6 2.5...25 4...50
With teminals 2 wire mm² 1...2.5 1...4 2.5...10 4...16
Hard wire 1 wire mm² 1...4 1.5..6 1.5...10 2.5...25 4...50
No terminal 2 wire mm² 1...4 1.5... 2.5...10 4...25
Fastening torque N ·m 1.2  1.8 
Coil
Rated control
voltage(Us)
50Hz V 24,36,48,110,127,220/230,240,380/400,415,440
50/60Hz V 24,36,48,110,127,220/230,240,380/400,415,440
Allowed control
circuit
voltage(Us)
Operation V Installation inclination angle±22.5°:85%~110%Us;Installation inclination angle±5°:70%~120%
Release V Installation inclination angle±22.5°:20%~75%Us;Installation inclination angle±5°:20%~65%
Power
onsumption
ofcail
Actuation VA 60  70  200  200 
Keep VA 6-9.5 6-9.5 15-20 15-20
Consumption W 1-3 1-3 6-10 6-10
Auxiliary contacts
Auxiliary contacts specification A 11 
Rated themal curent (lth) A 10 
Rated operating
voltage (Ue)
AC V 380 
DC V 220 
Rated control
capacity
AC-15 VA 360 
DC-13 W 33 
Certification CE,TUV,CB
 Type Amax Bmax Cmax a b c d e f
CJX2s-09, 12, 18 74.5 45.5 85.5 35 50/60 - - - -
CJX2s-25, 32, 38 83 56.5 97 40 50/70 - - - -
CJX2s-40, 50, 65 127.5 74.5 117 - - 105 40 100/110 59
CJX2s-80, 95 127.5 85.5 125.5 - - 105 40 100/110 67