General
1.Overload protection
2.Short circuit protection
3.Controlling
4.Used in residential building,non-residential building,energy source industry and infrastructure
5.According to thetypeof instantaneous releaseclassified as follows:type B(3-5)In,type C(5-10)In
CJX2s series AC Contactor with novel appearance and compact structure is suitablefor using starting &controlling the AC motor frequently,switching on and off thecircuitat a long distance.It is used in combinationwith thermal relay to compose amagneticmotor starter
StandardIEC60947-1,IEC 60947-4-1.
General
1.Protection against the effects of sinusoidal alternating earth fault currents
2.Protection against indirect contacts and additional protection against direct contacts
3.Protection against fire hazard caused byinsulation faults
4.Controlling and Switching
5.Used in residential building,non-residential building,energysources,industryand infrastructure
General
1.Protection against the effects of sinusoidal alternating earth fault currents
2.Protection against indirectcontacts and additional protection against direct contacts
3.Protection against fire hazard caused byinsulation faults
4.Controlling and Switching
5.Used in residential building,non-residential building,energy sources,industry and infrastructure
General
1.Protection againstoverload and short-circuit currents
2.Protection against the effectsof sinusoidal alternating earth fault currents
3.Protection against indirect contacts and additional protection against directcontacts.
4.Protection against fire hazard causedbyinsulation faults
5.Usedin residentialbuilding
6.According tothe type of instantaneousrelease classified as follows:type B(3-5)In,type C(5-10)In
General
1.Protection against overloadand short-circuit currents
2.Protection against the effects of sinusoidalalternatingearthfault currents
3.Protection against indirect contacts andadditional protection against direct contacts.
4.Protectionagainst fire hazard causedby insulation faults
5.Usedin residential building
6.According to the type of instantaneousrelease dassified as follows:type B(3-5)In,type C(5-10)In,type D(10-20)In
YCM3 Series moulded case circuit breaker,is new products,with small compact, modular,high break,double breakpoints,zero arcing,green environmen protection.Suitable for AC 50Hz,60Hz,rated operating voltage 690V and below, rated current 12.5A to 1600A distribution network,used to distribute electrical energy and protection lines and power supply equipment from overload,short circuit and undervoltage failure hazards.It can also be used as a non-frequent conversion of the line under normal conditions and in the infrequent start of the motor.
A modular DIN rail-mounted safety device designed for residential electrical systems, combining overload, short-circuit, and earth fault protection. Compliant with IEC/EN 61009-1 standards, it features a compact design, flame-retardant housing, and user-friendly functions like monthly test requirements, contact position indicators (red=ON, green=OFF), and a non-slip handle for reliable operation.
YCB7NLE-63 series RCBO is suitable for AC 50/60Hz, rated voltage up to 400V, rated current up to 63A circuits. It is used for leakage and overload protection for similar purposes to prevent fire or casualties caused by line leakage or electric shock.