NO NC Contactor – Normally Open vs Normally Closed Switch | CNC Electric
NO NC Contactor – Normally Open vs Normally Closed Switch
NO NC Contactor – Normally Open vs Normally Closed Switch
  • Product Overview

  • Product Details

  • Data Download

  • Related Products

NO NC Contactor – Normally Open vs Normally Closed Switch
Picture
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch
  • NO NC Contactor – Normally Open vs Normally Closed Switch

NO NC Contactor – Normally Open vs Normally Closed Switch

The YCC7 Series NO NC Contactor is a versatile, industrial-grade solution for motor control, designed to handle frequent starting/stopping of AC motors and remote circuit switching. Built to IEC 60947-1/4-1 standards, it combines robust performance with flexible customization, making it ideal for applications from small machinery to large-scale industrial systems. With rated currents from 6A to 630A and voltages up to 690V, the YCC7 series supports diverse setups—from 3P/4P configurations to auxiliary contact expansions for advanced control.

Contact Us

Product Details

Technical Highlights at a Glance

Parameter Details
Rated Current 6A–630A (AC-3)
Voltage 220V–690V AC
Poles 3P/4P
Auxiliary Contacts 1NO+1NC to 4NO+4NC (F4-D series)
Mechanical Life 120,000–1,200,000 cycles
Environmental Rating -35°C–+70°C, ≤2000m altitude
Certifications CCC, CE, TUV, CB

1. Flexible Configuration for Diverse Needs

Pole Options: Choose 3P (standard) or 4P (for neutral line inclusion) to match your system’s design.

Auxiliary Contacts: Customize with 1NO+1NC, 2NO+2NC, or up to 4NO/4NC modules (e.g., F4-DN20, F4-DN40) for precise status monitoring and control. Perfect for systems requiring 2 NO 2 NC contactors for safety interlocks or automation.

2. High Performance in Harsh Environments

Wide Temperature Range: Operates reliably from -35°C to +70°C (normal use: -5°C~+40°C), with derating guidance for extreme heat (e.g., 70°C = 75% capacity).

Altitude Adaptability: Certified for ≤2000m, with correction factors for higher elevations (e.g., 4000m = 78% impulse voltage capacity).

3. Long-Lasting Durability

Mechanical Life: Up to 1200,000 cycles (YCC7-M06-M16) for heavy-duty use.

Electrical Life: 110,000 cycles (AC-3) and 22,000 cycles (AC-4) ensure minimal downtime and lower replacement costs.

4. Scalable for Small to Large Systems

Current Range: 6A–630A covers everything from small pumps (YCC7-M06, 6A) to large motors (YCC7-630, 630A).

Voltage Compatibility: Supports 220V–690V AC, with AC-3/AC-4 ratings for resistive and motor loads (e.g., 55kW at 380V for YCC7-120).

5. Easy Installation & Integration

DIN Rail or Screw Mounting: Adapt to existing panels or new installations.

Wide Coil Voltage Options: AC/DC 12V–440V (50/60Hz) for global compatibility (e.g., 24V, 110V, 220V, 380V).

6. Expandable with Smart Accessories

Time-Delay Modules: LA2-DT0 (0.1s–3s) or LA3-DR4 (10s–180s) for sequenced motor control.

Surge Suppression: FS-M modules protect against voltage spikes in sensitive systems.

Reversing/Starter Kits: Pair with thermal relays for complete magnetic starters or reversing contactors.

YCC7 NO NC Contactor

Type designation

YCC7-M   □□   □□-/□
Product name Rated current Breaking capacity Breaking  capacity
YCC7-M □□ □□                                                                      □
Deslgn  Serial Number Rated current,expressed as the rated working current value of 400(380)V and AC-3(6A,9A,12A,16A) The  types  and  quantities  of  contacts,represented  by  numbers(re-
versible contactors represent the types and quantities of contacts for
a single product)
10:Indicating  three  normally  open  main  contacts  and  one  normally
open auxiliary contact
01:Indicating  three  normally  open  main  contacts  and  one  normally
closed auxiliary contact
08:Indicating two  normally open and two  normally closed  main con-
tacts
04:Indicating four normally open main contacts
Z represents DC op-
eration,N   represents
reversible AC contactor

 

YCC7-120   □□   □□-/□
Product name Rated current Breaking capacity    Breaking capacity
YCC7 120  AC220V 50/60Hz
YCC7 09,12,18,25,32,38,40,50,65,80,95,110,

120,160,185,225,265,330,400,500,630

48,110,127,220,230,240,380,400,415 50,60.50/60

Operating conditions

Type Operating and Installation Conditions
Installation category
Pollution level
Protection degree YCC7-M06-16A:IP20,YCC7-09~38:IP20;YCC7-40~95:YCC7-110 IP10,YCC7-120-630 IP10
Ambient temperature limit of temperature:-35°℃~+70℃,
normal temperature:-5℃~+40℃,
The average no more than +35℃ within 24 hours.
Altitude ≤2000m
Ambient temperature The maximum temperature is 70 degrees,the relative humidity of the air does not exceed 50%,and the temperature
below 50%can allow higher relative humidity.If the temperature is 20℃,the air relative humidity could up to 90%,
Special measures should be taken for occasional condensation due to humidity changes.
Installation position Inclination between installation surface and vertical surface should not exceed±5°
Shock vibration Products should be installed and used without significant shake,shock and vibration.

 

No. Three-phase asynchronous motor power
KW(AC-3)
Max Operating
Current(AC-3380V400V)
Contactor
Model
The number of auxiliary products
220V/230V 380V/400V 380V/400V Normally Open(NO) Normally Closed(NC)
1.5  2.2  YCC7-M0610 1 0
1.5  2.2  YCC7-M0601 0 1
2.2  YCC7-M0910 1 0
2.2  YCC7-M0901 0 1
2.2  5.5  YCC7-09 1 1
5.5  12  YCC7-M1210 1 0
5.5  12  YCC7-M1201 0 1
5.5  7.5  12  YCC7-12 1 1
7.5  7.5  16  YCC7-M1610 1 0
10  7.5  7.5  16  YCC7-M1601 0 1
11  7.5  10  18  YCC7-18 1 1
12  5.5  11  15  25  YCC7-25 1 1
13  7.5  15  18.5  32  YCC7-32 1 1
14  11  18.5  30  40  YCC7-40 1 1
15  15  22  37  50  YCC7-50 1 1
16  18.5  30  37  65  YCC7-65 1 1
17  22  37  37  75  YCC7-80 1 1
18  22  37  45  85  YCC7-95 1 1
19  25  45  45  100  YCC7-110 1 1
20  37  55  80  120  YCC7-120 2 2
21  45  75  100  160  YCC7-160 2 2
22  55  90  100  185  YCC7-185 2 2
23  63  110  110  225  YCC7-225 2 2
24  75  132  160  265  YCC7-265 2 2
25  90  160  200  330  YCC7-330 2 2
26  132  200  300  400  YCC7-400 2 2
27  160  250  335  500  YCC7-500 2 2
28  200  335  350  630  YCC7-630 2 2

Techniacal data

YCC7 Specifications
Main circuit characteristic
Type YCC7-M06 YCC7-M09 YCC7-M12 YCC7-M16
Poles
  3P,4P
Rated insulation voltage(Ui) V 690 
Rated operating voltage(Ue) V 380/400,660/690
Rated thermal current(Ith),AC-1 20  20  20  20 
Rated
operation
current(le)

Rated

AC-3,380/400V A 12  16 
AC-3,660/690V A 3.8  4.9  4.9  4.9 
AC-4,380/400V A 12 
AC-4,660/690V A 3.8  4.9  4.9  4.9 
operational
power(Pe)
AC-3,380/400V kW 2.2  5.5  7.5 
AC-3,660/690V kW
Mechanical life 10000
times
1200 
Electrical life AC-3 12 
AC-4 See electrical life curve
Frequency
of operation
AC-3 times/
hour
1200 
AC-4 300 
Connecting capability of main circuit terminal
Flexible wire wire mm² 1...4
No terminal 2 wire mm² 1...4
Flexible wire 1 wire mm² 1...4
With terminals 2 wire mm² 1..2.5
Hard wire 1 wire mm² 1...4
No terminal 2 wire mm² 1...4
Fastening torque N ·m 1.2 
Coil
Rated control
voltage(Us)
50Hz V 24,36,48,110,127,220,380,415
50/60Hz V 24,36,48,110,127,220,380,415
DC V 12,24,36,48,110,127,220
Allowed control
circuit
voltage(Us)
Operation V Installation inclination angle ±22.5°:85%~110%Us;Installation inclination angle±5°:70%~120%
Release(AC) V Installation inclination angle±22.5°:20%~75%Us;Installation inclination angle±5°:20%~60%
Release(DC) V Installation inclination angle ±22.5°:10%~75%Us;Installation inclination angle±5°:10%~60%
Power
consumption
of coil
Actuation VA 20-40
Keep VA 9.5 
Consumption W 1-3
Auxiliary contacts
Auxiliary contacts specification A 1NO+1NC
Rated thermal current(Ith) A 10 
Rated operating
voltage(Ue)
AC V 380/400
DC V 220 
Rated control
capacit
AC-15 VA Ue/le:AC380V/400V/1.5A Ith:10A
DC-13 W Ue/le:DC220V/0.3A
Certification CCC,CE,TUV,CB