A modular DIN rail-mounted safety device designed for residential electrical systems, combining overload, short-circuit, and earth fault protection. Compliant with IEC/EN 61009-1 standards, it features a compact design, flame-retardant housing, and user-friendly functions like monthly test requirements, contact position indicators (red=ON, green=OFF), and a non-slip handle for reliable operation.

Contact Us

Product Details

YCB9NL-40-RCBO-Modular

General

1.Protection against overload and short-circuit currents

2.Protection against the effects of sinusoidal alternating earth fault currents

3.Protection against indirect contacts and additional protection against direct contacts.

4.Protection against fire hazard caused by insulation faults

5.Used in residential building

6.According to the type of instantaneous release classified as follows:type B(3-5)ln,type C(5-10)ln

Selection

Type Test current Tripping time Expected result Type Test current Tripping time Expected result
B,C,D 1.13In t≤1h(In≤63A) Not tripping B 3In t≤0.1s Not tripping
1.13In t≤2h(In>63A)
C 5In t≤0.1s
B,C,D 1.45In t≤1h(In≤63A) Tripping
1.45In t<2h(In>63A) B 5In t<0.1s Tripping
B,C,D 2.25In 1s<t<60s(In≤32A) Tripping
C 10ln t<0.1s
2.25In 1s<t<120s(In>32A)

Curve

YCB9NL-40-RCBO-Curve

Technical data

Type Standard   IEC/EN61009-1
Electrical
features
Poles P 1P+N
Type(wave form of the earth leakage sensed)   AC
Thermal-magnetic release characteristic   B,C,D
Rated current In A 6,10,16,20,25,32,40
Rated voltage Ue V 230 
Rated sensitivity I△n A 0.03,0.05,0.1
Rated residual making and breaking capacity I△m A 500(In≤40A)630(In>40A)
Rated short-circuit capacity Icn A 6000 
Break time under I△n S ≤0.1
Rated frequency Hz 50/60
Rated impulse withstand voltage(1.2/50)Uimp V 4000 
Dielectric test voltage at ind.Freq.for 1min kV
Insulation voltage Ui V 500 
Pollution degree  
Mechanical
features
Electrical life t 4000 
Mechanical life t 10000 
Contact position indicator   Yes
Protection degree   IP20
Ambient temperature(with daily average≤35℃) -5~+40
Storage temperature -25~+70
Installation Terminal connection type   Cable/Pin-type busbar
Terminal size top/bottom for cable   mm² 16 
  AWG 18-5
Terminal size top/bottom for busbar   mm² 10 
  AWG 18-5
Tightening torque   N*m
In-Ibs 18 
Mounting   On DIN rail EN60715(35mm)by means of fast clip device
Connection   From top

Overall and mounting dimensions (mm)

YCB9NL-40-RCBO-Overall

Leave Your Message